1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Our Top Cities


Local Reviews
for park forest, il

Rated 5.0 out of 5 stars based on 2 customer reviews

Great 👍

Professional


Response from Trenchless Innovations Inc.:

Thanks for taking the time to share your experience with us, Davis! We appreciate your business and we are happy we could help uncover the issues with your underground air ducts. If you have additional questions, please don't hesitate to call our office at 708-758-5070. Thanks again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service Awesome Price

Fantastic moo


Response from Trenchless Innovations Inc.:

Thanks for your review, Ronald! We are happy to hear you had a great experience with us. Thank you for choosing us for your air duct lining - you're on your way to cleaner, healthier air! Happy Holidays to you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for park forest, il

Kevin W.

Kevin W. Job Checkin

I responded to a service call for a residential pipe repair in Park Forest, IL today. Upon inspection, I identified damage at the cleanout in the backyard, affecting the pipe leading to the main sewer line. I applied a temporary fix by inserting a line to address the critical issue. Additionally, I provided the homeowner with a detailed estimate for the complete replacement of the damaged pipe section.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are galvanized showing slight signs of rust. Will provide quote for lining ducts and possibly spin cast mortaring. Also televised sewer from pulled toilet. There are cracks in the street and also a piece of clay that is broken on top but still in place. Need to provide quote for installing a clean out in front yard then will be able to quote for installing a spot liner. Cast is channeled with a hole in the bottom of the tee at the stack.


Bob S.

Bob S. Job Checkin

Ductwork video inspection service call. Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. Cardboard is coming in on itself in several places. If ducts were to be kept in the floor they would need to be cleaned out then spin cast mortared and spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Ductwork video camera inspection service call. Televised ducts under slab floor. Ducts are cardboard with metal fitting and connections. There is heavy dirt and sand in the ducts. Ducts should be spin cast mortared then spray lined with Duct Armor duct lining material


Bob S.

Bob S. Job Checkin

Under slab leak detection service call. Televised ducts under slab floor. Ducts are cardboard and collapsed in several spots. Provide quote for breaking up floor then spin cast mortaring and spray lining.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings. Cardboard is collapsing in a few areas but my be able to be cleaned up. After ducts are cleaned they should be spin cast mortared then spray lined with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal elbows. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

We are applying the first application of duct armor to all of the underground asbestos transite air ducts.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily deteriorated underground cardboard air ducts.


Josh R.

Josh R. Job Checkin

We are applying our Trenchless Cast Mortar to all of the heavily deteriorated underground cardboard air ducts. This process will give the air ducts a strong concrete like structure.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. There was no standing water in ducts at time of the inspection but there were water marks indicating prior water in system. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are galvanized metal ducts. There are two locations where the pipes are collapsed and need to be dug up to be fixed. Once that is done the remainder of the system should be spin cast mortared then spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. The cardboard is showing signs of water contact and the plenum is rusted on the bottom and sides. Suggest spin cast mortaring the ducts to restore and ensure proper structure then spray lining ducts with Duct Armor duct lining material to provide a clean and healthy breathing environment.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground cardboard air ducts. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.


Kevin W.

Kevin W. Job Checkin

We are repairing the underground duct work in a slab home cardboard ducts that were molded and deteriorated, applying our trenchless cast to restructure and line with our rubberized duct lining material.